CBHBL - SYNCHRON CX SYSTEMS GLUCOSE REAGENT, 443355

  • MSDS: CBHBL
  • Manufacturer: BECKMAN INSTRUMENTS INC
  • Product Name: SYNCHRON CX SYSTEMS GLUCOSE REAGENT, 443355
  • National Stock Number: 6550-00N068104
Product Identification

Product ID:SYNCHRON CX SYSTEMS GLUCOSE REAGENT, 443355
MSDS Date:12/22/1986
FSC:6550
NIIN:00N068104
MSDS Number: CBHBL

Responsible Party
BECKMAN INSTRUMENTS INC
2500 HARBOR BLVD
FULLERTON, CA 92634-3100
US

Emergency Phone: 800-854-3633

Info Phone: 714-773-8061

Cage: 05721

Contractor
BECKMAN INSTRUMENTS INC SCIENTIFIC INSTRUMENTS DIV
FULLERTON, CA 92634 US

Telephone: 714-773-8061

Cage: 05721

Ingredients

POTASSIUM PHOSPHATE MONOBASIC

CAS: 7778-77-0

Fraction By Weight: 1.9%

OSHA PEL N/K

ACGIH TLV: N/K


POTASSIUM PHOSPHATE DIBASIC

CAS: 7758-11-4

Fraction By Weight: 1.9%

OSHA PEL N/K

ACGIH TLV: N/K


MOLYBDIC ACID, HEXAAMMONIUM SALT; (AMMONIUM MOLYBDATE).

CAS: 12027-67-7

RTECS: QA5076000

Fraction By Weight: 2.5%

OSHA PEL 5 MG/M3 (MO)

ACGIH TLV: 5 MG/M3 (MO)


MERCURY, ((O-CARBOXYPHENYL)THIO)ETHYL-, SODIUM SALT;

CAS: 54-64-8

RTECS: OV8400000

Fraction By Weight: 0.01%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:SEE INGREDIENT 3.
Routes of Entry: Inhalation:NO Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:MAY BE IRRITATING ON CONTACT WITH
EYES. MAY BE TOXIC IF INGESTED. NOTE:MERCURY COMPOUNDS APPEAR ON
THE NAVY LISTING OF OCCUPATIONAL CHEMICAL REPRODUCTIVE HAZARDS.
SEEK CONSULTATION FROM APPROPRIATE HE ALTH PROFESSIONALS CONCERNING
LATEST HAZARD LIST INFORMATION & SAFE HANDLING & EXPOSURE
INFORMATION .
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:SEE HEALTH HAZARDS.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.

First Aid

First Aid:INHAL:REMOVE TO FRESH AIR. SUPPORT BREATHING (GIVE O*2/ARTF
RESP) . EYES:IMMEDIATELY FLUSH W/POTABLE WATER FOR A MINIMUM OF 15
MINUTES, SEEK ASSISTANCE FROM MD . SKIN:FLUSH AFFECTED AREAS
W/WATER. CONSULT MD IF SYMPTOMS PERSIST. INGEST:CONSULT MD.

Fire Fighting

Flash Point:NOT FLAMMABLE
Extinguishing Media:MEDIA SUITABLE FOR SURROUNDING FIRE .
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT .

Accidental Release

Spill Release Procedures:ABSORB ON INERT MATERIAL FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:NO SPECIAL REQUIREMENT.
Other Precautions:NONE.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR APPROPRIATE FOR
EXPOSURE OF CONCERN . NOT REQUIRED.
Ventilation:NO SPECIAL REQUIREMENT.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:NONE.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

Boiling Pt:B.P. Text:212F,100C
Vapor Pres:18 @ 20C
Vapor Density:0.6
Spec Gravity:1 (H*2O=1)
Evaporation Rate & Reference:1 (H*2O=1)
Solubility in Water:AQUEOUS SOLUTION
Appearance and Odor:CLEAR AMBER SOLUTION; UNPLEASANT ODOR.
Percent Volatiles by Volume:>90

Stability

Stability Indicator/Materials to Avoid:YES
NONE.
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:OXIDES OF CARBON, MOLYBDENUM.

Disposal

Waste Disposal Methods:THIS MATERIAL MAY BE A HAZARDOUS WASTE & SHOULD
BE MANAGED I/A/W APPROPRIATE FEDERAL, STATE & LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.